GOVISC SPECIFICATION |
|
|
|
PERFORMANCE |
Range |
0 – 100,000cP over 5 models |
|
Measurement Time |
1 second |
|
Accuracy |
1% of reading or +/- 1 digit |
|
Repeatability |
0.3% of reading or +/- 1 digit |
OUTPUTS |
Analog |
4-20mA configurable, representing viscosity, ref. viscosity, or temperature |
|
Digital |
RS485 ModBus Data Link to host system or PC running ViscoLink |
|
USB |
USB II Plug and Play through VP100 Interface |
TEMPERATURE |
Integral Thermometer |
Integrated tip mounted temperature measurement |
|
Standard Range |
-20 °C to 150 °C |
|
Extended Range |
To order for greater than 150 °C * |
SENSOR PROJECTION |
Nominal sensor projection |
300mm |
ELECTRICAL CONNECTION |
Cable Length |
As required – not affected by cable length. |
|
Cable/Connector Type |
Tyco M9 |
|
Power |
USB powered through VP100 Interface |
CONSTRUCTION |
All welded, crevice-free |
MATERIALS |
Sensor |
SS316 ( EN 1.4401) |
|
Sensor Options: |
Alloy C22 (EN 2.4602) |
|
|
Alloy C276 (EN 2.4819) |
|
Special Materials: |
Non-standard materials to order * |
SURFACE FINISH |
Standard |
N5 0.4 Ra |
|
Finish Options |
Fluoropolymer |
|
|
Electropolished |
|
|
Electroplated |
|
Special Finish |
Non-standard finish options and coatings to order * |
WEIGHT |
|
700g |
INGRESS PROTECTION |
Standard |
IP65 |
SOFTWARE |
ViscoLink data viewing and logging PC software |
|
|
|
* Special Operations |
Custom variations to instrument specification and dimensions routinely provided by our dedicated Special Operations division |
|
|
|
As it is Hydramotion’s policy to continuously develop and improve its products, some specifications may change without notice |